1. Rugby Field Lighting Practices: Standard Intercollegiate Play

Following these recommended best practices will help ensure quality of light needed for the safety of participants and the enjoyment of spectators, as required.

Typical stadium seating: under 5.000 seats

Horizontal light levels: 50 footcandles

Horizontal uniformity: 2.0:1

Grid spacing: 30 ft x 30 ft

Recommended pole placement:

1.1 Special consideration for lighting placement is given to stadiums with customized roof mount potential.

1.2 Shaded areas indicate recommended pole location. All poles should be at least 45 feet from sideline.

1.3. On a 4-pole design, poles should be located between the 20-yard line and the goal line.

1.4 On a 6-pole design, setback of middle poles will depend on the presence of bleachers.

1.5 Pole placement and aiming angles shall be designed to minimize glare for players and spectators.

1.6 For new facilities or upgrades, it is recommended to consult a lighting professional for optimal pole placement.

2. Rugby Field Lighting Practices: Regional Broadcast

Following these recommended best practices will help ensure quality of light needed for the safety of participants, enjoyment of spectators, and quality regional television broadcasts, as required.

Typical stadium seating: 5.000 – 25.000 seats

Horizontal light levels: 75 footcandles

Horizontal uniformity: 2.0:1

Vertical light levels: 75 footcandles to 50-yard line high camera (main camera)

45 footcandles to end zone camera

Vertical uniformity: 2.0:1 to main camera

Grid spacing: 30 ft x 30 ft

Recommended pole placement:

2.1 Special consideration for lighting placement is given to stadiums with customized roof mount potential.

2.2 Shaded areas indicate recommended pole location. All poles should be at least 45 feet from sideline.

2.3 Setback of middle poles will depend on the presence of bleachers.

2.4 Outside poles should be located beyond end zone line. Optimum placement for TV is 15 degrees or greater off the end zone line for an end zone camera.

2.5 Pole placement and aiming angles shall be designed to minimize glare for players, spectators, and television cameras.

2.6 For new facilities or upgrades, it is recommended to consult a lighting professional for optimal pole placement.

3. Rugby Field Lighting Practices: National Broadcast

Following these recommended best practices will help ensure quality of light needed for the safety of participants, enjoyment of spectators, and quality national television broadcasts, as required.

Typical stadium seating: 25.000 – 45.000 seats

Horizontal light levels: 100 footcandles

Horizontal uniformity: 1.7:1

Vertical light levels: 100 footcandles to 50-yard line high camera (main camera)

60 footcandles to end zone camera

Vertical uniformity: 1.7:1 to main camera

Grid spacing: 30 ft x 30 ft

Recommended pole placement:

3.1 Special consideration for lighting placement is given to stadiums with customized roof mount potential.

3.2 Shaded areas indicate recommended pole location. All poles should be at least 45 feet from sideline.

3.3 Setback of middle poles will depend on the presence of bleachers.

3.4 Outside poles should be located beyond end zone line. Optimum placement for TV is 15 degrees or greater off the end zone line for an end zone camera.

3.5 Pole placement and aiming angles shall be designed to minimize glare for players, spectators, and television cameras.

3.6 The ratio of keylight to backlight main camera levels should be between 1:1 and 1.5:1. A ratio of 1:1 is preferred.

3.7 For new facilities or upgrades, it is recommended to consult a lighting professional for optimal pole placement.

4. Rugby Field Lighting Practices: National Broadcast Final Site

Following these recommended best practices will help ensure quality of light needed for the safety of participants, enjoyment of spectators, and quality national championship final site television broadcasts, as required.

Typical stadium seating: 45.000+ seats

Horizontal light levels: 125 footcandles Horizontal uniformity: 1.5:1

Vertical light levels: 125 footcandles to 50-yard line high camera (main camera)

75 footcandles to end zone camera

Vertical uniformity: 1.5:1 to main camera

2.5:1 to end zone camera

Grid spacing: 30 ft x 30 ft

Recommended pole placement:

4.1 Special consideration for lighting placement is given to stadiums with customized roof mount potential.

4.2 Shaded areas indicate recommended pole location. All poles should be at least 45 feet from sideline.

4.3 Setback of middle poles will depend on the presence of bleachers.

4.4 Outside poles should be located beyond end zone line. Optimum placement for TV is 15 degrees or greater off the end zone line for an end zone camera.

4.5 Pole placement and aiming angles shall be designed to minimize glare for players, spectators, and television cameras.

4.6 The ratio of keylight to backlight main camera levels should be between 1:1 and 1.5:1. A ratio of 1:1 is preferred.

4.7 For new facilities or upgrades, it is recommended to consult a lighting professional for optimal pole placement.